Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: transformerDescription: VB The PT series 230V AC 50 to 60Hz primary winding, single or double secondary winding, is used for series or parallel connection (for safety compliance reasons, transformers with 2 x 15 and 2 x 18V outputs, 0.35 to 3.2VA, and all transformers with 2 x 24V outputs should not have their secondary windings connected in series, as this means they will not comply with VDE 0550 certification). The VB series (0.35-3.2VA) has inherent short-circuit protection. The PT series (4.5-22VA) is protected by internal PTC equipment with a compact design vacuum epoxy resin molding, achieving UL94-V0 level dual load glass fiber reinforced polyamide wire spools with 100% electrical and insulation testing, high efficiency and low temperature rise, low capacitance between windings, and low radiation noise. Additional fixing holes are provided to ensure low noise between windings at 4.5V. Guidelines for Installing and Tightening the Upper Plate of VA and Higher Transformers (Double Secondary) - VA Rated value | Fixed center (mm) | | Pin configuration (mm) | | | | C1 | C2 | P1 | S1 | S2 | A | Pin size 0.35 | - | - | 15 | 5 | 5 | 15 | 0.6 Ø 0.5 | - | 15 | 5 | 5 | 15 | 0.6 Ø 1.0 | - | - | 20 | 10 | 20 | 0.8 Ø 1.5 | - | 20 | 10 | 5 | 20 | 5 | 20 | 5 | 0.8 Ø 2.3 | - | - | 20 | 10 | 5 | 20 | 0.8 Ø 3.2 | - | - | 20 | 10 | 25 | 0.8 Ø 4.5 | 35 | 28 | 25 | 15 | 5 | 25 | 0.8 Ø 7.5 | 40 | 32 | 25 | 15 | 5 | 27.5 | 0.8 Ø 13 | 47.5 | 37.5 | 30 | 20 | 5 | 30 | 0.8 Ø 22 | 52.5 | 40 | 30 | 10 | 32.5 | 0.8 Ø Isolation | | Primary to Secondary 5kV Secondary to Secondary 250V -------------------- | Protection Level | 2 Insulation: | VB Series PT Series | B Class (130 ° C) A Class (105 ° C) E Class (120 ° C) A Class (105 ° C) Fixed: Strengthen the mechanical fixation of 4.5 to 22VA transformers by using 4 self tapping screws (maximum size 4 x 9.5mm) and fixing holes at the corners of the box. || Maximum ambient temperature | 0.35 to 2.3VA+70 ° C, 3.2VA+50 ° C, 4.5 to 22VA+40 ° C | Selection guide (single secondary) - VA rating | Pin configuration (mm) |69371+$61.216810+$58.5552100+$58.0761250+$57.7035500+$57.11791000+$56.85182500+$56.47925000+$56.1598
-
Category: transformerDescription: 230V Communication primary VC/VCM series single or double secondary windings, used for series or parallel connection of vacuum epoxy resin molding, comply with UL94V-O low winding capacitance low radiation noise 100% electrical and insulation test additional fixing points, ensure board installation fastening (25 VA and 36 VA) note to comply with VDE 0550 standard, UL506 with output of 2 x 24V, all transformers should not be connected in series with secondary equipment. Recognized ENEC, UL certification standard EN 61 558 IEC 61558 Closed laminated - VC, VCM series99991+$48.265610+$45.4963100+$43.4391250+$43.1226500+$42.80611000+$42.45002500+$42.13355000+$41.9357
